+ 86-13361597190
180. zk, Wujia Village Industrial Park, Nanjiao Town, Zhoucun District, Zibo Hiria, Shandong Probintzia, Txina
+ 86-13361597190

2025-11-06
FBD-NO11.2# Mine explosion-proof axial flow fan is equipped with 45kw explosion-proof frequency conversion motor. Each fan is equipped with 2 motors, 2 impellers and 2 mufflers. The starting cabinet is explosion-proof frequency conversion control cabinet, which can be adjusted from 0 to 50Hz. It has large air volume and low noise.
FBD Mine Explosion-proof Axial Flow Fan. This product features a reasonable structure, complete specifications, high efficiency, obvious energy-saving effect, low noise, and long air supply distance. According to different ventilation resistance requirements, it can be used as a whole or in stages, thereby reducing ventilation power consumption and saving energy. For tunnels with a length of 2000m or less, the fan can be used for normal air supply without moving, reducing the labor intensity of workers, saving ventilation time, and making it an ideal equipment for local ventilation in coal mines. At the same time, it can also be used in high-pressure ventilation scenarios in industries such as metallurgy, non-ferrous metals, gold, chemical engineering, shipbuilding, and ceramics. Its structural characteristics are explosion-proof for mining, counter-rotating, noise reduction, and axial flow type.
Installation and commissioning
a. Equipment foundation, installation conditions and installation technical requirements
This series of fans do not require a dedicated equipment foundation. They can be placed on a relatively flat roadway floor and operate stably for a long time. When installed in a suspended manner, anchor rods should be driven at the position of the lifting ears on the top of the fan, and the U-shaped steel cable connection should be completed.
b. Commissioning procedures, methods and precautions
Remove the collector and diffuser of the fan, open the anti-fall wiring boxes at both ends of the motors, select the appropriate flame-retardant cable according to the motor power, thread the cable from the wiring boxes on the first and second main shell, connect it to the motor through the explosion-proof wiring box, install the wiring box and tighten the compression nut to secure the cable, and then connect the collector and diffuser. It should be noted that the wiring box of the motor is explosion-proof. As long as it is opened once, before re-connecting, the joint surface must be coated with industrial shellac or 107 anti-rust oil to ensure the explosion-proof performance of the motor.
Check whether the connection bolts of each part are complete and reliable. Manually rotate the two-stage impellers. When the rotation is flexible, the test run can be carried out and the commissioning work can be carried out.